From eScan Wiki
(Difference between revisions)
Revision as of 08:40, 3 July 2009
|
General |
Knowledgebase |
Support |
- eScan Monitor/firewall notification not getting updated in Windows Security center if WMI (Windows Management Instrumentation) database is corrupted.
Solution:
In order to repair WMI which places the eScan Monitor and firewall status in the Windows Security Center, Please use the following procedure
- Open an elevated command prompt
- Use the winmgmt.exe to check the consistency of WMI database using the command "winmgmt /verifyrepository". It will verify if there's any inconsistency with the database.
- If the need arises use command "winmgmt /salvagerepository" to repair it.
Note:The above procedure only works on Windows Vista and above
Email us your feedback to solutions@mwti.net